<?xml version='1.0'?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:georss="http://www.georss.org/georss" xmlns:atom="http://www.w3.org/2005/Atom" >
<channel>
	<title><![CDATA[BOL: Related items]]></title>
	<link>https://bioinformaticsonline.com/related/37524?</link>
	<atom:link href="https://bioinformaticsonline.com/related/37524?" rel="self" type="application/rss+xml" />
	<description><![CDATA[]]></description>
	
	<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/37473/lsc-a-long-read-error-correction-tool</guid>
	<pubDate>Thu, 02 Aug 2018 07:39:46 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/37473/lsc-a-long-read-error-correction-tool</link>
	<title><![CDATA[LSC :a long read error correction tool]]></title>
	<description><![CDATA[<h2>Getting Started</h2>
<p>These simple steps will help you integrate LSC into your transcriptomics analysis pipeline.</p>
<ul>
<li>Read the&nbsp;<a href="https://www.healthcare.uiowa.edu/labs/au/LSC/LSC_requirements.asp">LSC_requirements</a>&nbsp;for running LSC.</li>
<li><a href="https://www.healthcare.uiowa.edu/labs/au/LSC/LSC_download.asp">Download</a>&nbsp;and set-up the LSC package.</li>
<li>Follow the&nbsp;<a href="https://www.healthcare.uiowa.edu/labs/au/LSC/LSC_tutorial.asp">tutorial</a>&nbsp;to see how LSC works on some example data.</li>
<li>Read the&nbsp;<a href="https://www.healthcare.uiowa.edu/labs/au/LSC/LSC_manual.asp">manual</a>&nbsp;if anything is unclear.</li>
<li>You're ready, Happy LSCing!</li>
</ul>
<h2>Latest publication</h2>
<p><span>Kin Fai Au, Jason Underwood, Lawrence Lee and Wing Hung Wong&nbsp;</span><br><strong>Improving PacBio Long Read Accuracy by Short Read Alignment&nbsp;</strong><span>[</span><a href="http://journals.plos.org/plosone/article?id=10.1371%2Fjournal.pone.0046679">Manuscript</a><span>]&nbsp;</span><br><em>PLoS ONE</em><span>&nbsp;2012. 7(10): e46679. doi:10.1371/journal.pone.0046679</span></p><p>Address of the bookmark: <a href="https://www.healthcare.uiowa.edu/labs/au/LSC/" rel="nofollow">https://www.healthcare.uiowa.edu/labs/au/LSC/</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/34475/oxford-nanopore-sequencing-hybrid-error-correction-and-de-novo-assembly-of-a-eukaryotic-genome</guid>
	<pubDate>Wed, 29 Nov 2017 05:08:53 -0600</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/34475/oxford-nanopore-sequencing-hybrid-error-correction-and-de-novo-assembly-of-a-eukaryotic-genome</link>
	<title><![CDATA[Oxford Nanopore Sequencing, Hybrid Error Correction, and de novo Assembly of a Eukaryotic Genome]]></title>
	<description><![CDATA[<p><span>Monitoring the progress of DNA molecules through a membrane pore has been postulated as a method for sequencing DNA for several decades. Recently, a nanopore-based sequencing instrument, the Oxford Nanopore MinION, has become available that we used for sequencing the S. cerevisiae genome. To make use of these data, we developed a novel open-source hybrid error correction algorithm Nanocorr (</span><a href="https://github.com/jgurtowski/nanocorr">https://github.com/jgurtowski/nanocorr</a><span>) specifically for Oxford Nanopore reads, as existing packages were incapable of assembling the long read lengths (5-50kbp) at such high error rate (between ~5 and 40% error). With this new method we were able to perform a hybrid error correction of the nanopore reads using complementary MiSeq data and produce a de novo assembly that is highly contiguous and accurate: the contig N50 length is more than ten-times greater than an Illumina-only assembly (678kb versus 59.9kbp), and has greater than 99.88% consensus identity when compared to the reference. Furthermore, the assembly with the long nanopore reads presents a much more complete representation of the features of the genome and correctly assembles gene cassettes, rRNAs, transposable elements, and other genomic features that were almost entirely absent in the Illumina-only assembly.</span></p><p>Address of the bookmark: <a href="http://schatzlab.cshl.edu/data/nanocorr/" rel="nofollow">http://schatzlab.cshl.edu/data/nanocorr/</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/36884/halc-high-throughput-algorithm-for-long-read-error-correction</guid>
	<pubDate>Fri, 08 Jun 2018 10:47:41 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/36884/halc-high-throughput-algorithm-for-long-read-error-correction</link>
	<title><![CDATA[HALC: High throughput algorithm for long read error correction]]></title>
	<description><![CDATA[HALC, a high throughput algorithm for long read error correction. HALC aligns the long reads to short read contigs from the same species with a relatively low identity requirement so that a long read region can be aligned to at least one contig region, including its true genome region’s repeats in the contigs sufficiently similar to it (similar repeat based alignment approach)

HALC was able to obtain 6.7-41.1% higher throughput than the existing algorithms while maintaining comparable accuracy. The HALC corrected long reads can thus result in 11.4-60.7% longer assembled contigs than the existing algorithms.<p>Address of the bookmark: <a href="https://github.com/lanl001/halc" rel="nofollow">https://github.com/lanl001/halc</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/32129/lordec-a-hybrid-error-correction-program-for-long-pacbio-reads</guid>
	<pubDate>Mon, 10 Apr 2017 04:16:09 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/32129/lordec-a-hybrid-error-correction-program-for-long-pacbio-reads</link>
	<title><![CDATA[LoRDEC: a hybrid error correction program for long, PacBio reads]]></title>
	<description><![CDATA[<p>LoRDEC is a program to correct sequencing errors in long reads from 3rd generation sequencing with high error rate, and is especially intended for PacBio reads. It uses a hybrid strategy, meaning that it uses two sets of reads: the reference read set, whose error rate is assumed to be small, and the PacBio read set, which is then corrected using the reference set. Typically, the reference set contains Illumina reads.</p>
<p><br> Usually, errors in PacBio reads include many insertions and deletions, and comparatively less substitutions. LoRDEC can correct errors of all these types.<br> After correction, a larger portion of the sequence of PacBio reads is usable for detection of region of similarity with other sequences, for aligning them to the contigs of an assembly, etc.</p>
<p>Why is LoRDEC different?</p>
<ul>
<li>It is efficient and can process large read data sets, included from eukaryotic or vertebrate species, on a usual computing server, and even works on desktop/laptop computers.</li>
<li>It adopts a novel graph based approach: it builds a succinct De Bruijn Graph (DBG) representing the short reads, and seeks a corrective sequence for each erroneous region of a long read by traversing chosen paths in the graph.</li>
</ul><p>Address of the bookmark: <a href="http://www.atgc-montpellier.fr/lordec/" rel="nofollow">http://www.atgc-montpellier.fr/lordec/</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/35057/ectools-long-read-correction-and-other-correction-tools</guid>
	<pubDate>Fri, 05 Jan 2018 04:02:22 -0600</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/35057/ectools-long-read-correction-and-other-correction-tools</link>
	<title><![CDATA[ECTOOLS: Long Read Correction and other Correction tools]]></title>
	<description><![CDATA[<p>Long Read Correction and other Correction tools</p>
<p>This package is a loose collection of scripts. To run the correction<br>routine see the section below. Descriptions of the other scripts<br>are at the bottom of this file.</p>
<p>Contact: gurtowsk@cshl.edu</p>
<p>In short, the correction algorithm takes as input the unitigs from a short read assembly and uses them to correct long read data. More background information for the algorithm can be found:<br>http://schatzlab.cshl.edu/presentations/2013-06-18.PBUserMeeting.pdf</p><p>Address of the bookmark: <a href="https://github.com/jgurtowski/ectools" rel="nofollow">https://github.com/jgurtowski/ectools</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/37561/hercules-a-profile-hmm-based-hybrid-error-correction-algorithm-for-long-reads</guid>
	<pubDate>Mon, 20 Aug 2018 14:14:11 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/37561/hercules-a-profile-hmm-based-hybrid-error-correction-algorithm-for-long-reads</link>
	<title><![CDATA[Hercules: a profile HMM-based hybrid error correction algorithm for long reads]]></title>
	<description><![CDATA[<p><span>Choosing whether to use second or third generation sequencing platforms can lead to trade-offs between accuracy and read length. Several studies require long and accurate reads including de novo assembly, fusion and structural variation detection. In such cases researchers often combine both technologies and the more erroneous long reads are corrected using the short reads. Current approaches rely on various graph based alignment techniques and do not take the error profile of the underlying technology into account. Memory- and time- efficient machine learning algorithms that address these shortcomings have the potential to achieve better and more accurate integration of these two technologies. Results: We designed and developed Hercules, the first machine learning-based long read error correction algorithm. The algorithm models every long read as a profile Hidden Markov Model with respect to the underlying platformtextquoterights error profile. The algorithm learns a posterior transition/emission probability distribution for each long read and uses this to correct errors in these reads. Using datasets from two DNA-seq BAC clones (CH17-157L1 and CH17-227A2), and human brain cerebellum polyA RNA-seq, we show that Hercules-corrected reads have the highest mapping rate among all competing algorithms and highest accuracy when most of the basepairs of a long read are covered with short reads. Availability: </span></p>
<p><span>Hercules source code is available at https://github.com/BilkentCompGen/Hercules</span></p><p>Address of the bookmark: <a href="https://github.com/BilkentCompGen/Hercules" rel="nofollow">https://github.com/BilkentCompGen/Hercules</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/40889/rcorrector-efficient-and-accurate-error-correction-for-illumina-rna-seq-reads</guid>
	<pubDate>Tue, 04 Feb 2020 23:23:16 -0600</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/40889/rcorrector-efficient-and-accurate-error-correction-for-illumina-rna-seq-reads</link>
	<title><![CDATA[Rcorrector: efficient and accurate error correction for Illumina RNA-seq reads]]></title>
	<description><![CDATA[<p><span>Rcorrector has an accuracy higher than or comparable to existing methods, including the only other method (SEECER) designed for RNA-seq reads, and is more time and memory efficient. With a 5 GB memory footprint for 100 million reads, it can be run on virtually any desktop or server. The software is available free of charge under the GNU General Public License from&nbsp;</span><a href="https://github.com/mourisl/Rcorrector/" target="_blank">https://github.com/mourisl/Rcorrector/</a><span>.</span></p>
<pre><code>Usage: perl run_rcorrector.pl [OPTIONS]
OPTIONS:
	Required
	-s seq_files: comma separated files for single-end data sets
	-1 seq_files_left: comma separated files for the first mate in the paried-end data sets
	-2 seq_files_right: comma separated files for the second mate in the paired-end data sets
	-i seq_files_interleaved: comma sperated files for interleaved paired-end data sets
	Optional
	-k INT: kmer_length (&lt;=32, default: 23)
	-od STRING: output_file_directory (default: ./)
	-t INT: number of threads to use (default: 1)
	-trim : allow trimming (default: false)
	-maxcorK INT: the maximum number of correction within k-bp window (default: 4)
	-wk FLOAT: the proportion of kmers that are used to estimate weak kmer count threshold, lower for more divergent genome (default: 0.95)
	-ek INT: expected number of kmers; does not affect the correctness of program but affects the memory usage (default: 100000000)
	-stdout: output the corrected reads to stdout (default: not used)
	-verbose: output some correction information to stdout (default: not used)
	-stage INT: start from which stage (default: 0)
		0-start from begining(storing kmers in bloom filter) ;
		1-start from count kmers showed up in bloom filter;
		2-start from dumping kmer counts into a jf_dump file;
		3-start from error correction.</code></pre><p>Address of the bookmark: <a href="https://github.com/mourisl/Rcorrector/" rel="nofollow">https://github.com/mourisl/Rcorrector/</a></p>]]></description>
	<dc:creator>BioStar</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/36755/minialign-fast-and-accurate-alignment-tool-for-pacbio-and-nanopore-long-reads</guid>
	<pubDate>Thu, 24 May 2018 08:33:26 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/36755/minialign-fast-and-accurate-alignment-tool-for-pacbio-and-nanopore-long-reads</link>
	<title><![CDATA[minialign: fast and accurate alignment tool for PacBio and Nanopore long reads]]></title>
	<description><![CDATA[Minialign is a little bit fast and moderately accurate nucleotide sequence alignment tool designed for PacBio and Nanopore long reads. It is built on three key algorithms, minimizer-based index of the minimap overlapper, array-based seed chaining, and SIMD-parallel Smith-Waterman-Gotoh extension.<p>Address of the bookmark: <a href="https://github.com/ocxtal/minialign" rel="nofollow">https://github.com/ocxtal/minialign</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/32868/pollux-platform-independent-error-correction-of-single-and-mixed-genomes</guid>
	<pubDate>Fri, 19 May 2017 09:41:27 -0500</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/32868/pollux-platform-independent-error-correction-of-single-and-mixed-genomes</link>
	<title><![CDATA[Pollux: platform independent error correction of single and mixed genomes]]></title>
	<description><![CDATA[<p><span>Pollux: General-purpose error corrector that corrects errors introduced by Illumina, Ion Torrent, and Roche 454 sequencing technologies and can be applied to single- or mixed-genome data. In addition to correcting substitution errors, we locate and correct insertion, deletion, and homopolymer errors while remaining sensitive to low coverage areas of sequencing projects. Using published data sets, we correct 94% of Illumina MiSeq errors, 88% of Ion Torrent PGM errors, 85% of Roche 454 GS Junior errors. Introduced errors are 20 to 70 times more rare than successfully corrected errors. Furthermore, we show that the quality of assemblies improves when reads are corrected by our software.</span></p>
<p><span>https://bmcbioinformatics.biomedcentral.com/articles/10.1186/s12859-014-0435-6</span></p><p>Address of the bookmark: <a href="https://github.com/emarinier/pollux" rel="nofollow">https://github.com/emarinier/pollux</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>
<item>
	<guid isPermaLink="true">https://bioinformaticsonline.com/bookmarks/view/35059/lrcstats-long-read-correction-statistics</guid>
	<pubDate>Fri, 05 Jan 2018 04:04:20 -0600</pubDate>
	<link>https://bioinformaticsonline.com/bookmarks/view/35059/lrcstats-long-read-correction-statistics</link>
	<title><![CDATA[LRCstats: Long Read Correction Statistics]]></title>
	<description><![CDATA[<p>LRCstats is an open-source pipeline for benchmarking DNA long read correction algorithms for long reads outputted by third generation sequencing technology such as machines produced by Pacific Biosciences. The reads produced by third generation sequencing technology, as the name suggests, are longer in length than reads produced by next generation sequencing technologies, such as those produced by Illumina. However, long reads are plagued by high error rates, which can cause issues in downstream analysis. Long read correction algorithms reduce the error rate of long reads either through self-correcting methods or using accurate, short reads outputted by next generation sequencing technologies to correct long reads.</p>
<p>Of course, some long read correction algorithms are better than others, and developers of long read correction algorithms will wish to compare their algorithm with others currently available. LRCstats benchmarks long read correction algorithms using long reads produced by simulators (such as SimLoRD or PBSim) where the two-way alignments between the uncorrected long reads (uLR) and the corresponding sequences in the reference genome (Ref) are given in some sort of alignment file and then aligning the corrected long reads (cLR) to the Ref-uLR two-way alignments to create three-way alignments using a dynamic programming algorithm. Statistics on these three-way alignments are then collected, such as the overall error rates of the corrected long reads.</p>
<p>https://www.healthcare.uiowa.edu/labs/au/LSC/</p><p>Address of the bookmark: <a href="https://github.com/cchauve/lrcstats" rel="nofollow">https://github.com/cchauve/lrcstats</a></p>]]></description>
	<dc:creator>Jit</dc:creator>
</item>

</channel>
</rss>